Flexseal Logo

Global Leaders in Flexible Couplings, Drainage & Plumbing Systems


Return to "Lateral Connections"

TA Saddle

Used to connect a lateral pipe into a smooth walled main pipe.

Connect a 110mm, 160mm or 200mm OD lateral pipe into a large diameter smooth wall pipe, including concrete, vitrified clay, asbestos cement, fibre cement and PVC.

 TA200 45TA SADDLE TA SADDLE 90

Performance:

  • Available for both 45° and 90° lateral connections
  • Will withstand 0.5 bar internal pressure
  • Can be applied to pipes of any wall thickness
  • Seal made on the pipe surface, and secured with straps, which pass around the outside of the main pipe

Application Range:

  TA11090 TA11045 TA16090 TA16045 TA20045
External diameter of main pipe 160-400mm 160-400mm 200-400mm 200-400mm 300-600mm
Lateral pipe 110mm PVC 110mm PVC 160mm PVC 160mm PVC 200mm PVC
Hole size into clay/concrete pipe 127mm core bit See Note 172/178mm core bit See Note See Note
Hole size into PVC pipe 127mm hole saw See Note 177mm hole saw See Note See Note


Note: If a 45º entry into PVC is required, the rubber gasket can be used as a template and the hole cut with a suitable saw. If a 45º entry into clay or concrete is required, a suitable drilling rig should be used.